A bypass orifice was invented to control the refrigerant flow in an inverter heat pump system. Flow characteristics of a bypass orifice were measured as a function of orifice geometry and operating conditions, and test results were compared with the results of capillary tubes. The bypass orifice showed the best flow trend as a function of frequency; the flow slope of a bypass orifice with respect to frequency was the highest among orifice, capillary, and bypass orifice. The performance of an inverter heat pump with a bypass orifice was measured with a variation of frequency in the psychrometric test room. It Was observed that the performance of an inverter heat pump was enhanced by applying a bypass orifice instead of a capillary tube. The improvement of COP was obvious at low frequency level.