Attempts have been made to increase the effective damping in building systems. One of the attempts is mass type vibration control devices such as TMD, AMD which transmit inertial force to the building to reduce its motion. But Spacing restrictions will not permit traditional TMD configurations, requiring the installation of alternative configuration, including inverted pendulums, systems with mechanically-guided slide tables and laminated rubber bearings. In this study, a method to reduce the size of TMD is provided. The method is to control the stoke of TMD by increasing dry friction between moving mass and support frame of TMD as it move far from neutral points. Numerical simulation shows that the stoke of TMD is reduced but the performance is almost the same in case the friction is rapidly increased in the range of the end of stroke. The reason is that control force generated by TMD inertia is nearly correlated with the magnitude of the stroke. It means that the control force is very small at the end of stroke.