There were several performed studies on Steel Concrete(SC) Composite Column, which was developed to complement the weaknesses and maintain the advantages of previous composite columns, The axial compressive capacity of SC composite column was estimated by the tests in the pervious studies, but the experiments for the large-scale column could not be performed because of the lack of the laboratory capacity. In this study, the analytical study was performed using the general finite element analysis program to reflect the interaction of concrete and steel and the local buckling of steel flange composed of the non-compact section, The appropriateness of analytical model was verified by the comparison between experimental and analytical results, Nonlinear behavior of full-scaled SC composite column was analyzed using the verified analytical model. From these analytical studies, it was concluded that the width-to-thickness ratio of steel cross section of SC composite column should not exceeded 25.0. The section area of link is desirable to be over 0.025 dㆍt, and the link distance is to be less than D/2 or 300㎜.

목차

Abstract
1. 서론
2. SC 합성 기둥의 비선형 해석
3. 해석 변수 연구
4. 결론
참고문헌