This study is to investigate an optimal size and position of PV system for apartment complex trough the electrical load matching analysis. The 4 types of arrangements of apartment buildings are considered as follows ; -type, alternative -type, type and type. We assume that the studied site is composed of 9 buildings. Firstly, solar access evaluation of roof and facade in apartment buildings was performed with the hourly simulations of total received insolation on each surface considering the hading effect of buildings. Electrical load profile of typical Korean apartments was investigated for the sad matching analysis. To calculate an annual total PV output, we used MERIT program which is a curly based load matching tool developed by ESRU. TRY weather data of Daejeon are applied for this analysis.
Result shows that approximately 11% of total electric load of the site can be supplied by the PV system in the case of full installation of PV system at the whole south-face roof area of 9 buildings in this stuided apartment complex. Depending of a various installation option of roof and facade area, the ossible ratio of PV supply in total electrical load varies from 9% to 42%. Among the 4 arrangement types, the - type revealed the best option for the maximum output of PV system.

목차

Abstract
1. 서론
2. PV 시스템 설치 가용면적 및 평가방법
3. 단지규모 PV 전기부하매칭 평가 결과
4. 배치유형별 PV시스템 부하매칭 평가 결과
5. 결론
후기
참고문헌

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

이 논문과 함께 이용한 논문

최근 본 자료

전체보기

댓글(0)

0

UCI(KEPA) : I410-ECN-0101-2010-563-001428183