In general, conventional sheeting H-pile is often used as a temporary member installed upon construction of outer retaining wall at basement floor. However, it is noted that H-pile and reinforced concrete wall with certain thickness can be effectively composited by shear connectors.
Hence, in order to acquire possible higher resistances from composite behaviors of both H-pile and concrete wall structure, this study intends to study the behavior of shear studs for composite wall structure under shear stress, and know the effects of higher ductility from using U-reinforcement and stirrup with different forms of shear connector.
Push out test is performed for four specimens and their resistances are analyzed. From the test, the shear resistance was increased by using U or closed C type connectors.

목차

Abstract
1. 서론
2. 지하합성벽
3. 실험
4. 실험결과 및 분석
5. 결론
감사의 글