메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
저널정보
한국한의학연구원 한국한의학연구원 논문집 한국한의학연구원논문집 제14권 제2호
발행연도
2008.8
수록면
107 - 112 (6page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
Although the pulse diagnosis position, Guan is apart from Cun or Chi by only 10~20 ㎜ at most, traditional medical doctors applies different indent pressures and even they states different pulse images are felt at Cun, Guan and Chi. To support their clinical behaviors, in this study, we tested statistically whether there are differences in pulse waveform measured at these three positions with SphygmoCor system used world widely. A 30 years old female subject without any evidence of cardiovascular diseases was involved in this experiment. Radial pulse waves were recorded at three different positions on left lower arm 10 times at three positions - Cun, Guan and Chi. With ANOVA, we tested whether, among three different positions, there are any differences in 12 parameters of radial pulse waveform and in estimated AIx(Augmentation Index) as an arterial stiffness index extracted from radial pulse waveform. As results, differences in optimal indent pressure h0 were observed at different measuring positions (P < 0.001) but not significantly different. And pulse pressure h1s were found to be different (Chi < Cun < Guan). From these results, Oriental Medical doctors' diagnostic behavior of applying different indent pressures and their statements of plural pulse images can be asserted to be reasonable. On the other hand, estimated aortic AIx at Cun, Guan and Chi were 22.60 ± 3.06%, 18.60 ± 3.37% and 26.4 ± 5.02% respectively. Consequently, AIx at Gwan seems to be lowest and that at Chi seems to be highest. So, we assert the AIx at Chi is likely to be overestimated. In further studies, we want to examine what make differences in these parameters between measuring positions. And it also seems to be worthy to investigate the relationship between the depth of radial artery and AIx. And, ultimately, we need to determine the best measuring process including measuring position, hold-down pressure, signal quality validation and so on, so to achieve the optimal waveform which represents subject's health condition for both western medicine and traditional medicine

목차

Ⅰ. 서론
Ⅱ. 연구 방법
Ⅲ. 결과 및 고찰
Ⅳ. 결론
Ⅴ. 감사의 글
Ⅵ. 참고문헌

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

이 논문과 함께 이용한 논문

최근 본 자료

전체보기

댓글(0)

0