초록· 키워드

오류제보하기
In order to recommend criteria for the administration law on indoor air quality, this study was conducted to examine the distribution and the concentration of indoor air pollutants (PM₁?, CO₂, CO, HCHO, TBC, NO₂, Rn, VOCs, asbestos, O₃) in public facilities in the Chung-Nam area. The concentrations of indoor air pollutants were obtained from sixty seven public facilities such as a cinema, an office, a restaurant, a theater and an academy. This study was performed from August to December, 2005. The results of this study showed that the concentrations of indoor air pollutants such as PM₁?, CO₂, CO, HCHO, TBC, Rn and O₃ were less than the recommended limits. However, the average concentration of VOCs was 521.73㎍/㎥ (GM : 221.69㎍/㎥), which was higher than the recommended limit of 400 ㎍/㎥. Moreover, the average concentration of NO₂ was 345.66ppb (GM : 69.95ppb), which was higher than the recommended limit of 50 ppb. The correlation between the concentrations of indoor air pollutants and the type of facilities with respect to CO₂, TBC and Rn was statistically low (p<0.05). However, the correlation was high in terms of the CO and O₃ concentrations (p<0.01). No relationship between the indoor air pollutants and the type of facilities was observed for PM₁?, VOCs and NO₂. The year of construction was compared to the concentrations of indoor air pollutants. Specifically, when the construction date was less than 3 years, the HCHO, VOCs and TBC concentrations were 44.75 ㎍/㎥, 555.07 ㎍/㎥and 337.79 CFU/㎥, respectively. These concentrations were 120 ㎍/㎥and 211.84 CFUl㎥ higher for VOCs and TBC than the concentrations obtained from the facilities more than 3 years. However, the concentration of HCHO was similar between the facilities older and younger than 3 years of age. Year, temperature, humidity and indoor air pollutant correlation analyses showed that temperature and humidity, temperature and TBC, temperature and O₃, PM₁? and NO₂, HCHO and VOCs, CO₂ and Rn had positive relationships. However temperature and Rn, humidity and CO₂, CO₂ and O₃, Orand Rn had negative relationships. Accordingly, it will be necessary to manage the factors affecting indoor air quality so that the residents can have a more comfortable and healthier living environment. Ultimately, the results of this study are expected to be utilized as baseline data.

목차

Abstract
Ⅰ. 서론
Ⅱ. 연구대상 및 방법
Ⅲ. 연구 결과
Ⅳ. 결론
참고문헌

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

이 논문과 함께 이용한 논문

최근 본 자료

전체보기

댓글(0)

0

UCI(KEPA) : I410-ECN-0101-2009-517-019433304