Research has importance in proposing the design of a tunnel with a vertical vent to secure passengers in a comfortable environment and safe against pressure. Using several analysis methods, the magnitude of the pressure induced by the vertical vent in the tunnel can be analyzed. In addition to the 3-dimensional method, the 2-dimensional method and the 2-dimensional axis-symmetric method are also used to analyze the strong and weak points of each so that the optimum analysis method can be obtained. As a result, it appears that the 2-dimensional axis-symmetric method is the most suitable in analyzing tunnel pressure consider to accuracy and time effective aspect. Also, the 3-dimensional method is disadvantageous in that it takes longer in calculating results, but is more effective in predicting phenomena around the vertical vent in the tunnel.