메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
Paulson Samuel (Motilal Nehru National Institute of Technology) M. Kishore Naik (University of Padua) Rajesh Gupta (Motilal Nehru National Institute of Technology) Dinesh Chandra (Motilal Nehru National Institute of Technology)
저널정보
전력전자학회 JOURNAL OF POWER ELECTRONICS JOURNAL OF POWER ELECTRONICS Vol.14 No.2
발행연도
2014.3
수록면
271 - 281 (11page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
Fluctuating wind conditions necessitate the use of a variable speed wind turbine (VSWT) with a AC/DC/AC converter scheme in order to harvest the maximum power from the wind and to decouple the synchronous generator voltage and frequency from the grid voltage and frequency. In this paper, a combination of a three phase diode bridge rectifier (DBR) and a modified topology of the diode clamped multilevel inverter (DCMLI) has been considered as an AC/DC/AC converter. A control strategy has been proposed for the DCMLI to achieve the objective of grid interface of a wind power system together with local load compensation. A novel fixed frequency current control method is proposed for the DCMLI based on the level shifted multi carrier PWM for achieving the required control objectives with equal and uniform switching frequency operation for better control and thermal management with the modified DCMLI. The condition of the controller gain is derived to ensure the operation of the DCMLI at the fixed frequency of the carrier. The converter current injected into the distribution grid is controlled in accordance with the wind power availability. In addition, load compensation is performed as an added facility in order to free the source currents being fed from the grid of harmonic distortion, unbalance and a low power factor even though the load may be unbalanced, non-linear and of a poor power factor. The results are validated using PSCAD/EMTDC simulation studies.

목차

Abstract
Ⅰ. INTRODUCTION
Ⅱ. SPEED AND POWER RELATIONS OF A WIND TURBINE
Ⅲ. WIND ENERGY INTERFACE TO THE GRID USING A VSI IN THE CURRENT CONTROL MODE
Ⅳ. CAPACITOR VOLTAGE BALANCING STRATEGY
Ⅴ. MODELING AND CONTROL OF A DCMLI USING THE PROPOSED FIXED SWITCHING FREQUENCYCURRENT CONTROL METHOD
Ⅵ. CURRENT GENERATION ALGORITHM FOR THREE-PHASE SYSTEMS
Ⅶ. SIMULATION RESULTS
Ⅷ. CONCLUSIONS
REFERENCES

참고문헌 (22)

참고문헌 신청

이 논문의 저자 정보

이 논문과 함께 이용한 논문

최근 본 자료

전체보기

댓글(0)

0

UCI(KEPA) : I410-ECN-0101-2015-500-001245929