Jae-Hwan Cho (Hallym University of Graduate Studies) Jin-Hyeok Lee (Hallym University of Graduate Studies) Cheol-Soo Park (Hallym Polytechnic University) Sun-Yeob Lee (Hallym Polytechnic University) Jin Lee (Hallym University of Graduate Studies) Deog-Hwan Moon (Inje University) Hae-Kag Lee (Soonchunhyang University)
저널정보
한국자기학회 Journal of Magnetics Journal of Magnetics Vol.19 No.3
발행연도
2014.9
수록면
248 - 254 (7page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
The purpose of this study is to figure out how uptake counts of technetium (<SUP>99m</SUP>Tc) among radioisotopes in the human body are affected if computed tomography (CT), magnetic resonance imaging (MRI) and isotope examination are performed consecutively. <SUP>99m</SUP>Tc isotope material, iodinated contrast media for CT and paramagnetic contrast media for magnetic resonance (MR) were used as experimental materials. First, <SUP>99m</SUP>Tc was added to 4 cc normal saline in a test tube. Then, 2 cc of CT contrast media such as Iopamidol<SUP>®</SUP> and Dotarem<SUP>®</SUP> were diluted with 2 cc normal saline, and 2cc of MRI contrast media such as Primovist<SUP>®</SUP> and Gadovist<SUP>®</SUP> were diluted with 2 cc normal saline. Each distributed contrast media was a total of 4 cc and included 10m Ci of <SUP>99m</SUP>Tc. A gamma camera, a LEHR (Low energy high resolution) collimator and a pin-hole collimator were used for image acquisition. Image acquisition was repeated a total of 6 times and 120 frames were obtained and uptake counts of <SUP>99m</SUP>Tc were measured (from this procedure). In this study, as a result of measuring the uptake counts of <SUP>99m</SUP>Tc using the LEHR collimator, the uptake counts were less measured in all contrast media than normal saline as a reference. In particular, the lowest uptake counts were measured when Gadovist<SUP>®</SUP>, contrast media for MRI, was used. However, the result of measuring the uptake counts of <SUP>99m</SUP>Tc using the pin-hole collimator showed higher uptake counts in all contrast media, except for Iopamidol<SUP>®</SUP>, than normal saline as a reference. The highest uptake counts were measured particularly when Primovist<SUP>®</SUP>, contrast media for MRI, was used. In performing the gamma camera examination using contrast media and <SUP>99m</SUP>Tc, it is considered significant to check the changes in the uptake counts to improve various diagnosis values.

목차

1. Introduction
2. Materials and Methods
3. Results
4. Discussion
5. Conclusion
References

참고문헌 (0)

참고문헌 신청

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0