Field Application of Phased Array Ultrasonic Testing for Structural Weld Overlay on Dissimilar Welds of Pressurizer Nozzles
Recommendations
Search
Questions

가압기 노즐 이종금속 용접부의 구조적 오버레이 용접부에 대한 위상배열 초음파기법의 현장 적용

논문 기본 정보

Type
Academic journal
Author
Jin-Hoi Kim (한수원중앙연구원) Yongsik Kim (한수원중앙연구원)
Journal
The Korean Society For Nondestructive Testing JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING Vol.35 No.4 KCI Accredited Journals
Published
2015.8
Pages
268 - 274 (7page)

Usage

cover
📌
Topic
📖
Background
🔬
Method
🏆
Result
Field Application of Phased Array Ultrasonic Testing for Structural Weld Overlay on Dissimilar Welds of Pressurizer Nozzles
Ask AI
Recommendations
Search
Questions

Abstract· Keywords

Report Errors
Weld overlay was first used in power plants in the US in the early 1980s as an interim method of repairing the welds of flawed piping joints. Weld overlaid piping joints in nuclear power plants must be examined periodically using ultrasonic examination technology. Portable phased array ultrasonic technology has recently become available. Currently, the application of preemptive weld overlays as a mitigation technique and/as a method to improve the examination surface condition for more complex configurations is becoming more common. These complex geometries may require several focused conventional transducers for adequate inspection of the overlay, the original weld, and the base material. Alternatively, Phased array ultrasonic probes can be used to generate several inspection angles simultaneously at various focal depths to provide better and faster coverage than that possible by conventional methods. Thus, this technology can increase the speed of examinations, save costs, and reduce radiation exposure. In this paper, we explain the general sequence of the inspection of weld overlay and the results of signal analysis for some PAUT (phased array ultrasonic testing) signals detected in on-site inspections.

Contents

초록
Abstract
1. 서론
2. 구조적 용접 오버레이 검사
3. 위상배열 초음파검사
4. 오버레이 용접부 검사 결과
5. 결론
참고문헌

References (4)

Add References

Recommendations

It is an article recommended by DBpia according to the article similarity. Check out the related articles!

Related Authors

Frequently Viewed Together

Comments(0)

0

Write first comments.

UCI(KEPA) : I410-ECN-0101-2016-530-001835883