메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술대회자료
저자정보
저널정보
대한환경공학회 대한환경공학회 학술발표논문집 대한환경공학회 2006년도 춘계학술발표논문집
발행연도
2006.12
수록면
408 - 425 (18page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
Ultraviolet (UV) air disinfection is one of the engineering control methods utilized to control airborne transmission of pathogenic microorganisms in high risk settings. However, despite the recent emergence of respiratory viral pathogens such as SARS coronavirus and avian influenza viruses, UV air disinfection of viral aerosols is poorly studied. Hence, we characterized UV disinfection of viral aerosols using MS2, adenovirus, and coronavirus. The objectives of this study are (1) characterize the effect of nebulization and air sampling on the survival of tested viruses; (2) quantitatively estimate UV susceptibilities of these viral aerosols; (3) evaluate the effect of relative humidity (RH) on the susceptibility of viral aerosols to UV irradiation. A bench-size experimental chamber was built and evaluated for this study. MS2, adenovirus, or coronavirus was aerosolized into the experimental chamber, exposed to different UV doses, at either 50% or 75-80% RHs, and then sampled by AGI-30 liquid impinger at 12.5 LPM. The collected samples were analyzed by plaque assays to measure the UV susceptibilities of tested viral aerosols. Our data indicated that neither nebulization nor air sampling using liquid impinger caused significant inactivation of non-enveloped viruses such as MS2 or adenovirus. However, coronavirus was significantly inactivated by both nebulization and air sampling. Both MS2 and adenoviruses were very resistant to UV air disinfection. Less than 1 log reduction in viable virus was observed at the 2.6 mJ/㎠ UV dose for both viruses. However, coronavirus was more susceptible to UV air disinfection, which suggests that UV air disinfection could be an efficient environmental control method to prevent airborne transmission of novel SARS coronavirus. There was no significant protective effect of high RH on UV susceptibilities of the tested viral aerosols. Finally, our study also confirmed that UV disinfection rates of viral aerosols are much different from those of viruses suspended in water.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0

UCI(KEPA) : I410-ECN-0101-2017-539-001455446