메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
Xiao-ming LI (Northeast Dianli University) Xi ZHANG (Guang Dong Electric Power Research Institute) Zhong-wei LIN (North China Electric Power University) Yu-guang NIU (North China Electric Power University) Ming-yang LI (North China Electric Power University) Noel Vishal Nathan (Water bottling Company)
저널정보
대한전기학회 Journal of Electrical Engineering & Technology Journal of Electrical Engineering & Technology Vol.11 No.5
발행연도
2016.9
수록면
1,116 - 1,127 (12page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
For low investment and flexible control, doubly fed induction generator (DFIG) is becoming the dominant type that is been used in the wind farms (WFs) today. The report researches about the rotor-side controller of DFIG where all design is based on the single machine infinite bus (SMIB) model. The interactions between the different generators have not been considered in the SMIB model, and the desired performance cannot be obtained by using the controller based on this model. In this situation, an adaptive decentralized-coordinated multiple model predictive control (ADM-MPC) is proposed. First, the interaction measurement method is developed to obtain the interaction measurement model of DFIG, where the interactions between the different generators have been considered. Next, an adaptive multiple MPC based on the obtained interaction measurement method of DFIG is employed to control the rotor-side converter of DFIG. In order to cope with the stochastic disturbance of wind turbine, the augment state structure is employed to improve the tracking control performance. An artificial neural network (ANN) trained online is employed as a weighting controller to cope with the nonlinearities and large operating range of DFIG. A simple, generic renewable power system (RPS) is used to demonstrate contributions. The results of both dominant eigenvalue analysis and time response simulations are represented to illustrate contributions to system damping and transient stability that the DFIG based WF can make with the proposed ADM-MPC controller.

목차

Abstract
1. Introduction
2. Models of the RPS system
3. ADM-MPC Design Method
4. Dominant Eigenvalue Analysis and Simulation
5. Conclusions
References

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0

UCI(KEPA) : I410-ECN-0101-2017-560-000981628