Purpose: With the increase in the energy consumption in the building sector, many studies have recently been conducted to address this issue. Due to its efficiency, diverse studies on a light-shelf, which is a natural lighting system, are in progress. However, there has been no research on the external illumination that determines the performance of a light-shelf. Therefore, the present study aimed to prepare the external illumination standard for securing the lighting performance of a light-shelf through the light-shelf performance evaluation based on a 1:1 scale testbed, and to suggest a height-adjustable light-shelf based on an open and closed concept for the case in which the lighting performance of the light-shelf significantly deteriorates, by collecting the external illumination. Method: In this study, a 1:1 scale testbed was established for performance evaluation, and the external illumination standard for securing the performance of the light-shelf was prepared by comparing the lighting performance of the light-shelf depending on the open and closed condition of the light-shelf and the external illumination. Result: 1) In this study, a light-shelf that can be opened or closed depending on the external illumination was suggested. As a result, the prospect right can be secured by creating the condition where there is no light-shelf installation by moving the light-shelf to the top of the window when the lighting performance is not secured. 2) In the summer solstice, the external illuminations appropriate for lighting energy reduction were more than 75,000 lx and 60,000 lx for the light-shelf width of 0.3 m and 0.6 m, respectively. 3) In the intermediate period, the external illumination appropriate for lighting energy reduction was 60,000 lx. In the winter solstice, making the condition where there is no light-shelf installation by closing the light-shelf would be appropriate. 4) Based on the aforementioned results, the external illumination standard for the opening and closing of the height-adjustable light-shelf based on an open and closed concept suggested in this study was 60,000 lx, and the light-shelf with a width of 0.6 m would be advantageous for lighting energy reduction.

목차

ABSTRACT
1. 서론
2. 광선반의 개념 및 실내적정 조도 기준
3. 제안 및 성능평가
4. 결론
Reference

참고문헌 (18)

참고문헌 신청
Department of Energy, “2011 Buildings Energy Data Book”, 2011 조일식, 김기세, 윤종호, 이진숙, “Lightscape를 이용한 광선반의 주광 성능 해석 및 평가”, 한국태양에너지학회 춘계학술발표회, 2001 // (Cho Ilsik, Kim, Yoon Jongho, Analysis and estimate the perfomance of lightshelf system using lightscape. The Korean Solar Energy Society, 2001.05) 문기훈, 김정태, “Lightscape를 이용한 광선반의 창호시스템의 채광성능평가”, 한국생태환경건축학회 논문집, 제4권 제4호, 2004 // (Moon, Kihoon, Kim, Jeong Tai, Daylighting Performance Evaluation of Lightshelf Window System by Lightscape. Korea Institute of Ecological Architecture and Environment, Vol.4, No.4, 2004.12) dbpia 김정태, 김기철, 김곤, “Mock-up model을 이용한 경사형광선반 채광시스템의 개발 및 채광성능 평가에 관한 연구”, 한국태양에너지학회 , 제24권 제 2호, 2004 // (Kim, Jeongtai, Kim, Kicheol, Kim, Gon, Development and Performance Evaluation of a Sloped Lightshelf Daylighting System, Development and Performance Evaluation of a Sloped Lightshelf Daylighting System, Vol.24, No.2, 2004) 김봉균, 김정태, “광선반 유형에 따른 실내 채광특성에 관한 축소모형 실험적 연구”, 한국생태환경건축학회 학술발표대회 논문집 , 2005 // (Kim, Bongkyun, Kim, Jeong Tai, Scale Model Experiment for Daylighting Performance by Lightshelf Types. Korea Institute of Ecological Architecture and Environment, 2005.11)