Analysis of Infiltration of Outdoor Particulate Matter into Apartment Buildings
Recommendations
Search
Questions

외기 중 미세먼지의 공동주택 실내 유입에 관한 연구

논문 기본 정보

Type
Academic journal
Author
Bang, Jong-Il (세종대) Jo, Seong-Min (세종대) Sung, Min-Ki (세종대)
Journal
ARCHITECTURAL INSTITUTE OF KOREA JOURNAL OF THE ARCHITECTURAL INSTITUTE OF KOREA Structure & Construction Vol.34 No.1(Wn.351) KCI Excellent Accredited Journal
Published
2018.1
Pages
61 - 68 (8page)

Usage

cover
📌
Topic
📖
Background
🔬
Method
🏆
Result
Analysis of Infiltration of Outdoor Particulate Matter into Apartment Buildings
Ask AI
Recommendations
Search
Questions

Research history (3)

  • Are you curious about the follow-up research of this article?
  • You can check more advanced research results through related academic papers or academic presentations.
  • Check the research history of this article

Abstract· Keywords

Report Errors
Recently, concentration of fine and ultra-fine particulate matter(PM) has been increased in KOREA. The increase of PM in KOREA is due to increase of domestic industries and yellow dust from china. PM is known to cause diseases such as dyspnoea, asthma, arrhythmia. Since PM is harmful to human, KOREA Ministry of Environment(ME) warns people to stay indoors when the outdoor PM concentration is high. However, prior studies has shown that indoor PM concentration can be relatively high when outdoor PM concentration is high due to infiltration of PM into buildings though leakage areas. In this study, airtightness, indoor and outdoor pressure difference and PM 2.5 & 10 concentration were measured in an apartment complex to observe PM infiltrating into building. Field measurement was conducted in newly-built apartment buildings to avoid the influence of indoor PM which can be generated by residents. The airtightness test was conducted to identify the leakage areas of the apartment, such as electric outlets and supply/exhaust diffusers. The airtightness test result showed that the air leakage area of the building was dominant in buildings envelop. According to indoor and outdoor pressure difference measurement result and PM concentration measurement result, it can be concluded that outdoor PM can infiltrate into indoor by leakage areas when wind is blown toward the apartment. As a result, pressure difference formed by the external weather condition and architectural characteristics such as the airtightness in building can influence PM to infiltrate into buildings. In further studies, I/O ratio, stack-effect, infiltration and penetration factor will be considered.

Contents

Abstract
1. 서론
2. 연구 방법
3. 결과
4. 결론
REFERENCES

References (10)

Add References

Recommendations

It is an article recommended by DBpia according to the article similarity. Check out the related articles!

Related Authors

Frequently Viewed Together

Recently viewed articles

Comments(0)

0

Write first comments.

UCI(KEPA) : I410-ECN-0101-2018-540-001744863