저자정보
Hyun Soo Park (Shinhan University) Jong Ho Won (Citywall ENG) Woong June Chung (University of Bath)
저널정보
한국콘크리트학회 International Journal of Concrete Structures and Materials International Journal of Concrete Structures and Materials Vol.13 No.2
발행연도
2019.2
수록면
243 - 253 (11page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
In this research, a cable-type wall system that could replace the conventional aluminum curtain wall system for reinforced concrete high-rise buildings is proposed. The cable-type wall system is a newly developed system, which could be used as an existing exterior skin system, and can effectively support the wind load acting on the exterior of the high-rise buildings by the pre-induced initial tension force to the cable supporting the glass. The main advantages of the cable-type wall system are that the expense of construction could be reduced due to the simplicity of the construction. The experiment of structural analysis and air/water tightness was performed to evaluate its feasibility of industrialization. The structural performance of the cable-type wall system was evaluated through the structural analysis and the full-scale experiment to predict the initial pre-tension force and the design load displacement of the vertical one-way cable-type wall system that can be used for a typical floor of the high-rise building. The initial pretension force and structural behavior of the cable were analyzed by using the structural design program MIDAS-Gen. The maximum deformation value in the structural test was found to satisfy the AAMA condition, which is equal to the size of the facade skin system. The air/water tightness test was conducted to verify the performance. Test results show that the cable-type wall system satisfies the air/water tightness performance standards ASTM E283, E331 and AAMA 501.1-05 which are the most basic standards that the facade system must provide. As a result of this study, it is expected that the proposed cable-type wall system could be used for facade system, not only the structural performance but also air/water tightness performance are secured.

목차

Abstract
1 Introduction
2 Experimental Plan
3 Structural Analysis and Experimental Results
4 Conclusions
References