메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Results between different clinical laboratory measurement procedures (CLMP) should be equivalent, within clinically meaningful limits, to enable optimal use of clinical guidelines for disease diagnosis and patient management. When laboratory test results are neither standardized nor harmonized, a different numeric result may be obtained for the same clinical sample. Unfortunately, some guidelines are based on test results from a specific laboratory measurement procedure without consideration of the possibility or likelihood of differences between various procedures. When this happens, aggregation of data from different clinical research investigations and development of appropriate clinical practice guidelines will be flawed. A lack of recognition that results are neither standardized nor harmonized may lead to erroneous clinical, financial, regulatory, or technical decisions. Standardization of CLMPs has been accomplished for several measurands for which primary (pure substance) reference materials exist and/or reference measurement procedures (RMPs) have been developed. However, the harmonization of clinical laboratory procedures for measurands that do not have RMPs has been problematic owing to inadequate definition of the measurand, inadequate analytical specificity for the measurand,inadequate attention to the commutability of reference materials, and lack of a systematic approach for harmonization. To address these problems,an infrastructure must be developed to enable a systematic approach for identification and prioritization of measurands to be harmonized on the basis of clinical importance and technical feasibility, and for management of the technical implementation of a harmonization process for a specific measurand.

목차

등록된 정보가 없습니다.

참고문헌 (1)

참고문헌 신청
Kohn LT / 2000 / To err is human: building a safer health system / National Academy Press : 287 ~ | 2. [학술지(정기간행물)] - Vesper HW / 2009 / Traceability in laboratory medicine / Clin Chem 55 : 1067 ~ 1075 | 3. [기타자료] - ISO / 2003 / In vitro diagnostic medical devices-measurement of quantities in biological samples-metrological traceability of values assigned to calibrators and control materials. 1st ed / ISO 17511:2003(E) | 4. [학술지(정기간행물)] - Armbruster D / 2007 / The Joint Committee for Traceability in Laboratory Medicine (JCTLM): a global approach to promote the standardisation of clinical laboratory test results / Clin Biochem Rev 28 : 105 ~ 113 | 5. [학술지(정기간행물)] - Panteghini M / 2009 / Traceability as a unique tool to improve standardization in laboratory medicine / Clin Biochem 42 : 236 ~ 240 | 6. [학술지(정기간행물)] - Ekins R / 1991 / Immunoassay standardization / Scand J Clin Lab Invest 51 (205) : 33 ~ 46 | 7. [학술지(정기간행물)] - Thienpont LM / 2008 / Accuracy in clinical chemistry: who will kiss Sleeping Beauty awake? / Clin Chem Lab Med 46 : 1220 ~ 1222 | 8. [학술지(정기간행물)] - Zegers I / 2010 / Characterization of the new serum protein reference material ERM-DA470k/IFCC: value assignment by immunoassay / Clin Chem 56 : 1880 ~ 1888 | 9. [학술지(정기간행물)] - Little RR / 2008 / Standardization of C-peptide measurements / Clin Chem 54 : 1023 ~ 1026 | 10. [학술지(정기간행물)] - Stephan C / 2006 / Interchangeability of measurements of total and free prostate-specific antigen in serum with 5 frequently used assay combinations: an update / Clin Chem 52 : 59 ~ 64 | 11. [학술지(정기간행물)] - Miller WG / 2009 / Toward standardization of insulin immunoassays / Clin Chem 55 : 1011 ~ 1018 | 12. [학술지(정기간행물)] - Thienpont LM / 2010 / Report of the IFCC Working Group for Standardization of Thyroid Function Tests; part 1: thyroid-stimulating hormone / Clin Chem 56 : 902 ~ 911 | 13. [학술지(정기간행물)] - Rose MP / 1998 / Follicle stimulating hormone international standards and reference preparations for the calibration of immunoassays and bioassays / Clin Chim Acta 273 : 103 ~ 117 | 14. [학술지(정기간행물)] - Tate JR / 2010 / Standardisation of cardiac troponin I measurement: past and present / Pathology 42 : 402 ~ 408 | 15. [학술지(정기간행물)] - Sturgeon CM / 2009 / Differences in recognition of the 1st WHO international reference reagents for hCG-related isoforms by diagnostic immunoassays for human chorionic gonadotropin / Clin Chem 55 : 1484 ~ 1491 | 16. [학술지(정기간행물)] - Thienpont LM / 2010 / Traceability to a common standard for protein measurements by immunoassay for in-vitro diagnostic purposes / Clin Chim Acta 411 : 2058 ~ 2061 | 17. [학술지(정기간행물)] - Schimmel H / 2010 / Standardization of protein biomarker measurements: is it feasible? / Scand J Clin Lab Invest 70 (242) : 27 ~ 33 | 18. [학술지(정기간행물)] - Radin N / 1967 / What is a standard / Clin Chem 13 : 55 ~ 76 | 19. [학술지(정기간행물)] - Miller WG / 2006 / Why commutability matters / Clin Chem 52 : 553 ~ 554 | 20. [학술지(정기간행물)] - Vesper HW / 2007 / Reference materials and commutability / Clin Biochem Rev 28 : 139 ~ 147 | 21. [학술지(정기간행물)] - Caliendo AM / 2009 / A commutable cytomegalovirus calibrator is required to improve the agreement of viral load values between laboratories / Clin Chem 55 : 1701 ~ 1710 | 22. [기타자료] - CLSI / 2010 / Characterization and qualification of commutable reference materials for laboratory medicine: approved guideline / CLSI document C53-A | 23. [학술지(정기간행물)] - Franzini C / 1998 / Impact of reference materials on accuracy in clinical chemistry / Clin Biochem 31 : 449 ~ 457 | 24. [학술지(정기간행물)] - Thienpont LM / 2003 / Trueness verification in European external quality assessment schemes: time to care about the quality of the samples / Scand J Clin Lab Invest 63 : 195 ~ 202 | 25. [학술지(정기간행물)] - Miller WG / 2003 / Specimen materials, target values and commutability for external quality assessment (proficiency testing) schemes / Clin Chim Acta 327 : 25 ~ 37 | 26. [학술지(정기간행물)] - Bossuyt PM / 2003 / Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative / BMJ 326 : 41 ~ 44 | 27. [학술지(정기간행물)] - Roddam AW / 2004 / Assessing the clinical impact of prostate-specific antigen assay variability and nonequimolarity: a simulation study based on the population of the United Kingdom / Clin Chem 50 : 1012 ~ 1016 | 28. [학술지(정기간행물)] - / 2002 / NIH consensus statement on management of hepatitis C: 2002 / NIH Consens State Sci Statements 19 : 1 ~ 46 | 29. [학술지(정기간행물)] - Petersen PH / 2007 / ‘Likelihood-ratio’ and ‘odds’ applied to monitoring of patients as a supplement to ‘reference change value’ (RCV) / Clin Chem Lab Med 46 : 157 ~ 164 | 30. [학술지(정기간행물)] - Karon BS / 2010 / Glucose meter performance criteria for tight glycemic control estimated by simulation modeling / Clin Chem 56 : 1091 ~ 1097 | 31. [학술지(정기간행물)] - Kenny D / 1999 / Strategies to set global analytical quality specifications in laboratory medicine. Consensus agreement / Scand J Clin Lab Invest 59 : 475 ~ 585 | 32. [단행본] - Fraser CG / 2001 / Biological variation: from principles to practice / AACC Press | 33. [학술지(정기간행물)] - Braga F / 2010 / Panteghini M. Biological variability of glycated hemoglobin / Clin Chim Acta 411 : 1606 ~ 1610 | 34. [학술지(정기간행물)] - Miller WG / 2009 / Current issues in measurement and reporting of urinary albumin excretion / Clin Chem 55 : 24 ~ 38 | 35. [학술지(정기간행물)] - Miller WG / 2008 / State of the art in trueness and inter-laboratory harmonization for 10 analytes in general clinical chemistry / Arch Pathol Lab Med 132 : 838 ~ 846 | 36. [학술지(정기간행물)] - Palmer-Toy DE / 2005 / Comparison of pooled fresh frozen serum to proficiency testing material in College of American Pathologists surveys: cortisol and immunoglobulin E / Arch Pathol Lab Med 129 : 305 ~ 309 | 37. [학술지(정기간행물)] - Schreiber WE / 2005 / Comparison of fresh frozen serum to proficiency testing material in College of American Pathologists Surveys: α-fetoprotein, carcinoembryonic antigen, human chorionic gonadotropin, and prostatespecific antigen / Arch Pathol Lab Med 129 : 331 ~ 337 | 38. [학술지(정기간행물)] - Blirup-Jensen / 2001 / S. Protein standardization III: method optimization. Basic principles for quantitative determination of human serum proteins on automated instruments based on turbidimetry or nephelometry / Clin Chem Lab Med 39 : 1098 ~ 1109 google schola

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0