메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
은충기 (중앙대학교 의과대학 방사선과학교실)
저널정보
대한영상의학회 대한방사선의학회지 대한방사선의학회지 제13권 제1호
발행연도
1977.1
수록면
70 - 76 (7page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
The kidney size and its movability on the change of position from supine to erect by radiographic measurement provide an important value in the diagnosis and treatment of the renal disease. The lengh of the kidney, the ratio between the kidney length and the total height of the upper three lumbar vertebrae including intervertebral disc, the movable range of kidney in change of position from recumbent to erect and the distance from the left hilum to the right hilum were measured on intravenous pyelograms of 87 males and 97 females of the age of 20 to 59 years. The following results were obtained: 1. The radiographic measurement of kidney size and its movable range: {{{{sex }}{{age }}{{right kidney }}{{left kidney }}{{hilum(cm) }}{{length(cm) }}{{M(cm) }}{{K(ratio) }}{{length(cm) }}{{M(cm) }}{{K(ratio) }}{{male }}{{20-59 }}{{12.4$\pm$0.76 }}{{2.8$\pm$1.57 }}{{1.08$\pm$0.07 }}{{12.7$\pm$0.84 }}{{2.7$\pm$1.46 }}{{1.12$\pm$0.08 }}{{1.3$\pm$1.37 }}{{female }}{{20-59 }}{{12.0$\pm$0.98 }}{{3.5$\pm$1.52 }}{{1.13$\pm$1.10 }}{{12.4$\pm$0.97 }}{{3.0$\pm$1.45 }}{{1.16$\pm$0.10 }}{{1.1$\pm$1.24 }} }} (M: The mean of the movable range of kidney in change of position from supine to erect) (K: The ratio between the length of kidney and the total height of the upper three lumbar vertebrae including disc) 2. The size of kidney in male and the right kidney was smaller than in female and the left one, and mean difference was 0.3-0.4 cm. But the right kidney was larger in 25% of the cases than the left one. 3. The length of kidney was larger in 90% of the cases than the total height of the upper three lumbar vertebrae including disc. 4. The motion range of kidney in the change of position from supine to erect was 0-8.2 cm and the moving distance of the kidney in the right side and female was a little greater than that in the left kidney and male. 5. In 3% of the cases the kidney moved more than 6 cm in change of position from supine to erect. 6. The right hilum was usually lower in position than the left one. However, in 24 cases (13%) the right hilum was observed to be higher than the l ft one.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0