메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
전차선 (아트라스슬링운동센터) 김택연 (OPT 운동처방실)
저널정보
대한정형도수치료학회 대한정형도수물리치료학회지 대한정형도수물리치료학회지 제12권 제1호
발행연도
2006.1
수록면
37 - 43 (7page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
PURPOSE: Previous studies have documented the lack of ultrasound's non-thermal effects on nerve conduction using frequencies of 1 MHz and 870 kHz. The purpose of this study was to determine the biophysical effects of continuous ultrasound on median local forearm temperature and motor nerve conduction velocities using frequencies of 3.0 MHz. SUBJECTS: Twelve healthy subjects (6 males, 6 females, age $22.30{\pm}2.41$ yrs, weight $61.33{\pm}10.16$ kg, height $167.58{\pm}8.04$ cm) without a history of neurological or musculoskeletal injury to their dominant arm volunteered for this study. METHODS AND MATERIALS: Each subject received a total of five treatments, one each at .0, 0.5, 1.0, 1.5, 2.0 W/$cm^2$ of 3 MHz continuous ultrasound on the anterior surface of the middle area of dominant forearm for 10 minutes. Dependent measures for forearm local temperature and median motor nerve conduction velocity (MNCV) were taken pretreatment and immediately post-treatment. One-way ANOVA were used for each dependent measure. RESULTS: The posttreatment forearm local temperature were differed significantly (p<0.001) between intensities of ultrasound. The posttreatment forearm local temperature of the ultrasound treated with 1.0 w/$cm^2$, 1.5 w/$cm^2$ and 2.0 w/$cm^2$ were significantly higher than 0.5 w/$cm^2$ and 0.0 w/$cm^2$ of ultrasound (p<0.05). The posttreatment median MNCV were differed significantly from the respective pretreatment velocities (p<0.001). The MNCV of the ultrasound treated with 0.0 w/$cm^2$ and 0.5 w/$cm^2$ were significantly (p<0.05) slower than that observed pretreatment, while the three ultrasound intensities produced significantly increased posttreatment MNCV: 1.0 w/$cm^2$ and 1.5 w/$cm^2$ and 2.0 W/$cm^2$. The posttreatment MNCV at 2.0 w/$cm^2$ and 1.5 w/$cm^2$ was significantly faster than that at 0 w/$cm^2$, 0.5 w/$cm^2$ and 1.0 w/$cm^2$ (p<0.05), the MNCV at 1.0 w/$cm^2$ was significantly faster than that associated with 0 w/$cm^2$ and 0.5 w/$cm^2$ of ultrasound (p<0.05). CONCLUSIONS: The decreased median motor forearm local temperature and MNCV of the ultrasound treated with 0.0 w/$cm^2$ and 0.5 w/$cm^2$ were attributed to the cooling effect by ultrasound transmission gel. Local forearm temperature and nerve conduction velocity were directly related to the intensity of ultrasound. Alterations in MNCV from ultrasound on healthy nerves appeared to be related to temperature changes induced by thermal effects of ultrasound.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0