메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Shin, Miok (College of Pharmacy, Keimyung University) Ji, Dajeong (College of Pharmacy, Keimyung University) Kang, Soyoung (College of Pharmacy, Keimyung University) Yang, Wonkyung (National Forensic Service) Choi, Hwakyung (Southern District Office, National Forensic Service) Lee, Sooyeun (College of Pharmacy, Keimyung University)
저널정보
대한약학회 Archives of pharmacal research : a publication of the Pharmaceutical Society of Korea Archives of pharmacal research : a publication of the Pharmaceutical Society of Korea 제37권 제6호
발행연도
2014.1
수록면
760 - 772 (13page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
A recent trend in urine drug testing in forensic and clinical toxicology has been the simultaneous determination of different chemical groups of target drugs, which are selected based on their local popularity. Rapid multiple drug analysis, made possible by the use of liquid chromatography-tandem mass spectrometry (LC/MS/MS), has become more widely used, especially in workplace drug testing. Therefore, in the present study, a method for simultaneously analyzing 35 drugs of abuse and relevant metabolites that are most prevalent in Korea, using LC/MS/MS with polarity switching electrospray ionization, was developed and validated. The drugs and metabolites in urine were extracted by using mixed mode strong cation exchange polymeric solid phase extraction cartridges after enzymatic hydrolysis and were then injected into the LC/MS/MS system. The validation results for selectivity, linearity, intra- and inter-assay precision and accuracy for this method were satisfactory, while the results for matrix effects and recovery showed significant variance among the urine samples from different sources. The limits of detection ranged from 0.1 to 10 ng/ml and the limits of quantification were from 1 to 10 ng/ml. To reduce the matrix effects in authentic samples, two different quantitative approaches were compared: quantification using calibration standards prepared by the drug-free pooled urine matrix and quantification using the standard addition. Of these, the latter method was found to be the most suitable. The method developed in this study will be very useful for forensic and clinical toxicology laboratories to adopt for monitoring the inappropriate use of controlled drugs.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0