메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
De Molon, Rafael Scaf (Department of Diagnosis and Surgery, Araraquara Dental School, Universidade Estadual Paulista) Morais-Camillo, Juliana Aparecida Najarro Dearo (Department of Diagnosis and Surgery, Araraquara Dental School, Universidade Estadual Paulista) Sakakura, Celso Eduardo (Barretos Dental School, Barretos Educational Fundation) Ferreira, Mauricio Goncalves (Department of Diagnosis and Surgery, Araraquara Dental School, Universidade Estadual Paulista) Loffredo, Leonor Castro Monteiro (Department of Social Dentistry, Araraquara Dental School, Universidade Estadual Paulista) Scaf, Gulnara (Department of Diagnosis and Surgery, Araraquara Dental School, Universidade Estadual Paulista)
저널정보
대한영상치의학회 Imaging science in dentistry Imaging science in dentistry 제42권 제4호
발행연도
2012.1
수록면
243 - 247 (5page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Purpose: This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. Materials and Methods: Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Image manipulation (inversion) was performed using Adobe Photoshop 7.0 software. Four trained examiners made all of the radiographic measurements in millimeters a total of three times from the cementoenamel junction to the most apical extension of the bone loss with both types of images: inverted digital and film. The measurements were also made in dry mandibles using a periodontal probe and digital caliper. The Student's t-test was used to compare the depth measurements obtained from the two types of images and direct visual measurement in the dry mandibles. A significance level of 0.05 for a 95% confidence interval was used for each comparison. Results: There was a significant difference between depth measurements in the inverted digital images and direct visual measurements (p>|t|=0.0039), with means of 6.29 mm ($IC_{95%}$:6.04-6.54) and 6.79 mm ($IC_{95%}$:6.45-7.11), respectively. There was a non-significant difference between the film-based radiographs and direct visual measurements (p>|t|=0.4950), with means of 6.64mm($IC_{95%}$:6.40-6.89) and 6.79mm($IC_{95%}$:6.45-7.11), respectively. Conclusion: The periodontal bone defect measurements in the inverted digital images were inferior to film-based radiographs, underestimating the amount of bone loss.

목차

등록된 정보가 없습니다.

참고문헌 (16)

참고문헌 신청

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0