메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Dong, Ren G. (Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health) Sinsel, Erik W. (Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health) Welcome, Daniel E. (Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health) Warren, Christopher (Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health) Xu, Xueyan S. (Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health) McDowell, Thomas W. (Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health) Wu, John Z. (Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health)
저널정보
산업안전보건연구원 Safety and health at work : SH@W Safety and health at work : SH@W 제6권 제3호
발행연도
2015.1
수록면
159 - 173 (15page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
The hand coordinate systems for measuring vibration exposures and biodynamic responses have been standardized, but they are not actually used in many studies. This contradicts the purpose of the standardization. The objectives of this study were to identify the major sources of this problem, and to help define or identify better coordinate systems for the standardization. This study systematically reviewed the principles and definition methods, and evaluated typical hand coordinate systems. This study confirms that, as accelerometers remain the major technology for vibration measurement, it is reasonable to standardize two types of coordinate systems: a tool-based basicentric (BC) system and an anatomically based biodynamic (BD) system. However, these coordinate systems are not well defined in the current standard. Definition of the standard BC system is confusing, and it can be interpreted differently; as a result, it has been inconsistently applied in various standards and studies. The standard hand BD system is defined using the orientation of the third metacarpal bone. It is neither convenient nor defined based on important biological or biodynamic features. This explains why it is rarely used in practice. To resolve these inconsistencies and deficiencies, we proposed a revised method for defining the realistic handle BC system and an alternative method for defining the hand BD system. A fingertip-based BD system for measuring the principal grip force is also proposed based on an important feature of the grip force confirmed in this study.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0