Baik, Jee-Seon (School of Dentistry and Dental Research Institute, Seoul National University) Lee, Sam-Sun (School of Dentistry and Dental Research Institute, Seoul National University) Park, Kwan-Soo (Inje University, Sanggye Paik Hospital) Huh, Kyung-Hoe (School of Dentistry and Dental Research Institute, Seoul National University) Yi, Won-Jin (School of Dentistry and Dental Research Institute, Seoul National University) Heo, Min-Suk (School of Dentistry and Dental Research Institute, Seoul National University) Choi, Soon-Chul (School of Dentistry and Dental Research Institute, Seoul National University)
저널정보
대한영상치의학회 대한구강악안면방사선학회지 대한구강악안면방사선학회지 제37권 제4호
발행연도
2007.1
수록면
211 - 215 (5page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Purpose: The purpose of this study was to evaluate the effect of the kV on fractal dimension of trabecular bone in digital radiographs. Materials and Methods: 16 bone cores were obtained from patients who had taken partial resection of tibia due to accidents. Each bone core along with an aluminum step wedge was radiographed with an occlusal film at 0.08 sec and with the constant film-focus distance (32 cm). All radiographs were acquired at 60, 75, and 90 kV. A rectangular ROI was drawn at medial part, distal part, and the bone defect area of each bone core image according to each kV. The directional fractal dimension was measured using Fourier Transform spectrum, and the anisotropy was obtained using directional fractal dimension. The values were compared by the repeated measures ANOVA. Results : The fractal dimensions increased along with kV increase (p < 0.05). The anisotropy measurements did not show statistically significant difference according to kV change. The fractal dimensions of the bone defect areas of the bone cores have low values contrast to the non-defect areas of the bone cores. The anisotropy measurements of the bone defect areas were lower than those of the non-defect areas of the bone cores, but not statistically significant. Conclusion: Fractal analysis can notice a difference of a change of voltage of x-ray tube and bone defect or not. And anisotropy of a trabecular bone is coherent even with change of the voltage of x-ray tube or defecting off a part of bone.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0