메뉴 건너뛰기
Library Notice
Institutional Access
If you certify, you can access the articles for free.
Check out your institutions.
ex)Hankuk University, Nuri Motors
Log in Register Help KOR
Subject

A Study on the Implementation and Development of Image Processing Algorithms for Vibes Detection Equipment
Recommendations
Search
Questions

정맥 검출 장비 구현 및 영상처리 알고리즘 개발에 대한 연구

논문 기본 정보

Type
Academic journal
Author
Jin-Hyoung Jeong (가톨릭관동대학교) Jae-Hyun Jo (가톨릭관동대학교) Jee-Hun Jang (가톨릭관동대학교) Sang-Sik Lee (가톨릭관동대학교)
Journal
Korea Information Electron Communication Technology Journal of Korea Institute of Information, Electronics, and Communication Technology Vol.15 No.6 KCI Accredited Journals
Published
2022.12
Pages
463 - 470 (8page)

Usage

cover
📌
Topic
📖
Background
🔬
Method
🏆
Result
A Study on the Implementation and Development of Image Processing Algorithms for Vibes Detection Equipment
Ask AI
Recommendations
Search
Questions

Abstract· Keywords

Report Errors
Intravenous injection is widely used for patient treatment, including injection drugs, fluids, parenteral nutrition, and blood products, and is the most frequently performed invasive treatment for inpatients, including blood collection, peripheral catheter insertion, and other IV therapy, and more than 1 billion cases per year. Intravenous injection is one of the difficult procedures performed only by experienced nurses who have been trained in intravenous injection, and failure can lead to thrombosis and hematoma or nerve damage to the vein. Nurses who frequently perform intravenous injections may also make mistakes because it is not easy to detect veins due to factors such as obesity, skin color, and age. Accordingly, studies on auxiliary equipment capable of visualizing the venous structure of the back of the hand or arm have been published to reduce mistakes during intravenous injection. This paper is about the development of venous detection equipment that visualizes venous structure during intravenous injection, and the optimal combination was selected by comparing the brightness of acquired images according to the combination of near-infrared (NIR) LED and Filter with different wavelength bands. In addition, an image processing algorithm was derived to threshehold and making blood vessel part to green through grayscale conversion, histogram equilzation, and sharpening filters for clarity of vein images obtained through the implemented venous detection experimental module.

Contents

요약
Abstract
1. 서론
2. 연구 방법
3. 실험 결과 및 고찰
4. 결론
REFERENCES

References (0)

Add References

Recommendations

It is an article recommended by DBpia according to the article similarity. Check out the related articles!

Related Authors

Frequently Viewed Together

Recently viewed articles

Comments(0)

0

Write first comments.

UCI(KEPA) : I410-ECN-0101-2023-569-000290646