Han Aera (I-dream Clinic Department of Obstetrics and Gynecology MizMedi Hospital Seoul KoreaDeagu Cha Fertil) Suh Borum (Department of Laboratory Medicine MizMedi Hospital Seoul Korea) Yi Gwang (I-dream Clinic Department of Obstetrics and Gynecology MizMedi Hospital Seoul Korea) Lee Yoo Jin (I-dream Clinic Department of Obstetrics and Gynecology MizMedi Hospital Seoul Korea) Kim Sung Eun (I-dream Clinic Department of Obstetrics and Gynecology MizMedi Hospital Seoul Korea)
저널정보
대한진단검사의학회 Annals of Laboratory Medicine Annals of Laboratory Medicine 제42권 제1호
발행연도
2022.1
수록면
47 - 53 (7page)
DOI
10.3343/alm.2022.42.1.47

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Background: Since 2017, automated assays have been used in most clinical laboratories for anti-Mullerian hormone (AMH) level measurement. We evaluated the analytical performance of the newly developed automated fluorescent immunoassay system (AFIAS) AMH assay (Boditech Med, Gangwon-do, Korea) in comparison with the Roche Elecsys and Beckman Coulter Access 2 AMH assays. Methods: Analytical performance of the AFIAS AMH assay was assessed in terms of linearity, repeatability, and within-laboratory precision (CV%) using human recombinant AMH samples according to the Clinical and Laboratory Standards Institute (CLSI) guidelines EP05 and EP06. Using 293 serum samples collected from an infertility clinic, the AMH levels were compared across AFIAS, Elecsys, and Access 2 AMH assays according to the CLSI EP09 guidelines. Results: The AFIAS AMH assay results were linear across the measurement range of 0.420?72.386 pmol/L AMH, with repeatability of 6.341%. CV% of the AFIAS AMH assay for three levels of control, 1.786, 7.143, and 56.857 pmol/L, were 5.801%, 5.714%, and 6.228%, respectively. The results of the three AMH assays showed strong correlation: AFIAS and Elecsys [slope, 1.055 (95% confidence interval (CI), 1.022?1.088) and Spearman’s rho, 0.978 (95% CI, 0.973?0.983)], Elecsys and Access 2 [slope, 0.813 (95% CI, 0.791?0.834) and Spearman’s rho, 0.986 (95% CI, 0.983?0.989)], and AFIAS and Access 2 [slope, 0.836 (95% CI, 0.821?0.853) and Spearman’s rho, 0.984 (95% CI, 0.980? 0.988)]. Conclusions: The AFIAS AMH assay may be an alternative to the Roche Elecsys and Beckman Coulter Access 2 AMH assays.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0