Belhaj Omaima Essaad (Radiations and Nuclear Systems Laboratory Faculty of Sciences University Abdelmalek Essaadi) Boukhal Hamid (Radiations and Nuclear Systems Laboratory Faculty of Sciences University Abdelmalek Essaadi) Chakir El Mahjoub (LPMS Faculty of Sciences Ibn Tofail University) Bellahsaouia Meryeme (LPMS Faculty of Sciences Ibn Tofail University) Belhaj Siham (ENA Marrakech) Sadeq Younes (LPMS Faculty of Sciences Ibn Tofail University) Tazi Mohammed (SSDL National Center of Radiation Protection (CNRP)) El Khoukhi Tahar (National Center for Energy Science and Nuclear Technology) Hadouachi Maryam (Radiations and Nuclear Systems Laboratory Faculty of Sciences University Abdelmalek Essaadi) Laazouzi Khaoula (Radiations and Nuclear Systems Laboratory Faculty of Sciences University Abdelmalek Essaadi)
저널정보
한국원자력학회 Nuclear Engineering and Technology Nuclear Engineering and Technology 제55권 제2호
발행연도
2023.2
수록면
717 - 724 (8page)
DOI
10.1016/j.net.2022.10.029

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
An essential step in evaluating and comparing the performance of two passive radiation dosimeter types, thermosluminescent (TLD) and optically stimulated luminescence (OSL), used by workers in environments with ionizing radiation for individual radiological monitoring and control of external exposure at various times (cumulative dose for 1 month), is to compare the measured dose accuracy, energy response, and coefficient of variation. In fact this performance study consists in determining the accuracy of both R(10) and R(0.07) which are considered as the ratios of the measured dose (Hp(10) or Hp(0.07)) to the delivered dose (Hp(10) or Hp(0.07)) for each photon energy. The validity of the results of this test is based on the acceptance limits of the ICRP and the international standard IEC-62387. The relative energy response used is normalized to the 137Cs 662 keV energy to find which energy response is closest to the ideal case, and the coefficient of variation that allows to determine the statistical fluctuation of the Hp(10) and Hp(0.07) doses. The results of the accuracy test for the OSL and TLD dosimeters are acceptable because they fall within the ICRP limits. For the energy response, the OSL performs better than the TLD for Hp(10) and Hp(0.07), and for the coefficient of variation, the OSL satisfies the requirements of ISO 62387 for both Hp(10) and Hp(0.07), while the TLD satisfies these requirements only for the measurement of Hp (0.07).

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0