In the growing interest in renewable energy, the role of power converters has become more important. However, as the use of power converters is elevated, the negative effects of power conversion also increase because the grid-connected inverters not only convert energy but also generate harmonics that degrade grid quality by their switching behavior. Using an LCL filter is a cost-effective solution to mitigate switching harmonics in the grid-connected inverters especially compared with conventional L filters.
Although the LCL filters have superior attenuation ability, the entire system could be unstable because of the LCL filter’s resonance characteristic. Various passive or active damping methods have been proposed to solve this problem. Digital notch filter based methods are simple ways to stabilize the system among the methods. The methods inhibit the system resonance phenomenon by simply aligning the notch frequency to the resonance frequency. However, the system is only stable where the system resonance frequency is matched with notch frequency. In the real systems, there is a chance of resonance frequency variation caused by filter aging or grid impedance changing, therefore, the resonance frequency estimation is necessary to avoid the stability problem excited by variation of the system parameters. Some of the estimation methods were proposed to solve the problem. However, The conventional resonance frequency estimation methods have some drawbacks such as unavailability during operation state or very slow estimation time.
This paper proposes a new adaptive digital notch filter that has the ability to track the system resonance frequency to maintain the system stable even the system parameters are changed where the inverter side current is controlled. The system resonance frequency variation tracking speed is considerably improved compared to the conventional methods. The case that the system resonance frequency and the notch frequency are not matched is simulated and experimented to verify the validity of the proposed method. It is expected that the proposed method can be used in the field of the grid-connected inverter system with improved stability.

목차

제 1장 서 론 1
제 2장 LCL 필터가 결합된 단상 계통 연계형 인버터 시스템 4
2.1 PLL 5
2.1.1 SRF-PLL 5
2.1.2 SOGI-QSG 7
2.2 LCL 필터 9
2.2.1 S 도메인에서 LCL 필터 모델링 10
2.2.2 Z 도메인에서 LCL 필터 모델링 13
2.3 PR 제어기 17
2.4 노치 필터 21
제 3장 노치 필터가 사용된 계통 연계형 인버터의 안정도 판별 24
3.1 시스템의 안정도 판별법 24
3.2 플랜트를 불안정하게 만드는 요인 26
3.2.1 Z 변환 근사화에 의한 frequency wqrping 현상 27
3.2.2 딜레이에 의한 위상 지연 32
3.3 안정도 분석 35
3.3.1 노치 주파수와 공진 주파수가 일치하는 경우 36
3.3.2 노치 주파수와 공진 주파수가 일치하지 않는 경우 38
제 4장 제안하는 적응형 디지털 노치필터 43
4.1 공진 발생 여부 판단 44
4.1.1 시스템이 불안정할 경우 시스템 응답 44
4.1.2 공진을 나타내는 지표 46
4.2 공진 주파수 방향 판단 48
4.2.1 z 극점 위치에 따른 시스템 시간 응답 48
4.2.2 노치 주파수 변경에 따른 시스템 응답 50
제 5장 시뮬레이션 및 실험 결과 52
5.1 시뮬레이션 52
5.1.1 노치 주파수가 공진 주파수보다 높은 경우 53
5.1.2 노치 주파수가 공진 주파수보다 낮은 경우 55
5.2 실험 결과 57
제 6장 결 론 62
참고문헌 64
감사의 글 68