Dynamic Characteristics of Traditional Wooden Structure(Daeungjeon of Bongjeongsa) Excited by Historical Earthquake using Shaking Table
Recommendations
Search
Questions

진동대를 이용한 역사적 지진 작용 전통목구조(봉정사 대웅전)의 동적 특성

논문 기본 정보

Type
Academic journal
Author
Hwang, Jae-Seung (전남대) Hwang, Jong-Kook (한국전통문화대)
Journal
ARCHITECTURAL INSTITUTE OF KOREA JOURNAL OF THE ARCHITECTURAL INSTITUTE OF KOREA Structure & Construction Vol.31 No.11 KCI Excellent Accredited Journal
Published
2015.11
Pages
37 - 46 (10page)

Usage

cover
📌
Topic
본 논문은 동적 지진 하중이 한국 전통 목조건축의 응답 특성에 미치는 영향을 연구한다.
📖
Background
봉정사 대웅전은 15세기에 지어졌으며, 지진 발생 시 목조건축문화재의 반응 특성을 분석하기 위한 연구가 필요하다.
🔬
Method
1/3 크기로 축소된 모델이 5.5m x 4.5m 진동대에서 다양한 역사적 지진 신호를 이용하여 시험되었다.
🏆
Result
응답 크기가 증가하면서 고유진동수는 감소하고 고유감쇠비는 증가하며, 이러한 비선형 거동 특성이 목조건축물의 성능 개선에 기여할 것으로 기대된다.
Dynamic Characteristics of Traditional Wooden Structure(Daeungjeon of Bongjeongsa) Excited by Historical Earthquake using Shaking Table
Ask AI
Recommendations
Search
Questions

Abstract· Keywords

Report Errors
The objective of this paper is to investigate the response characteristics of Korean traditional wooden structure subject to dynamic earthquake load. To accomplish this research purpose, as a typical example of Korean traditional wooden structures, Bongjeong-sa(temple) constructed in the fifteenth century and classified as a treasure is selected. One-third scale model of Bongjeong-sa is designed and set up on a sliding table of 5.5m by 4.5m to perform shaking table test in the laboratory. To find similarity condition on the natural frequency between real structure and scaled test model, free vibration test was performed for real structure and test model. The natural frequencies of real structure were calculated from acceleration responses measured from ambient vibration test. The test model on shaking table was moved instantaneously toward x-direction of test model structure from 1mm to 10mm for the free vibration test while varying the roof mass in order to adjust similarity condition on the natural frequency. The earthquake signal of Elcentro, Kobe and Hachinohe were used to perform seismic test. The magnitude of earthquake acceleration was controlled as 4 types of 0.07g, 0.11g, 0.167g and 0.22g. The characteristic of instantaneous natural frequency and damping ratio with respect to the magnitude of displacement, velocity and acceleration responses of roof were analyzed.

AI Summary

Topic

본 논문은 동적 지진 하중이 한국 전통 목조건축의 응답 특성에 미치는 영향을 연구한다.

Background

봉정사 대웅전은 15세기에 지어졌으며, 지진 발생 시 목조건축문화재의 반응 특성을 분석하기 위한 연구가 필요하다.

Method

1/3 크기로 축소된 모델이 5.5m x 4.5m 진동대에서 다양한 역사적 지진 신호를 이용하여 시험되었다.

Result

응답 크기가 증가하면서 고유진동수는 감소하고 고유감쇠비는 증가하며, 이러한 비선형 거동 특성이 목조건축물의 성능 개선에 기여할 것으로 기대된다.

주요내용

Contents

Abstract
1. 서론
2. 실험모델 동적상사
3. 지진이력실험
4. 결론
REFERENCES