메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
저널정보
대한의용생체공학회 의공학회지 의공학회지 제38권 제2호
발행연도
2017.1
수록면
62 - 73 (12page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

이 논문의 연구 히스토리 (2)

초록· 키워드

오류제보하기
To identify a solution for the restricted availability of healthy lungs and the high risk of immune rejections following organ transplantation, tissue engineering techniques for culturing lungs have been studied by many research groups. The most promising method for culturing lungs is the utilization of a bio-scaffold that was prepared using harvested organs from human donors or other animals by removing their original cells. In this study, a pulsatile perfusion pump was used to alleviate the cell removal effect with the high fluid-dynamic power of the perfusion stream during the decellularization process, while other conventional studies focused on chemical methods to identify efficient detergents. The purpose of this study was to analyze the developed device by using energy equivalent pressure (EEP), which is an indicator of pulsatility, to understand the characteristics of pulsatile energy transmitted according to the load size by using the artificial model and compare it with the measured EEP. The pulsatility of the device can be estimated with the concept of fluid-dynamic energy during a particular constant time period or fluiddynamic power represented as EEP and EEP increment. Because the measured EEP of perfusion flow during decellularization can be changed by the amount of fluid leakage and the degree of clogging in the capillary vessels, EEP should be measured to determine whether the decellularization is progressing without problems. The decrement of EEP caused by the high perfusion resistance was observed from some experimental results that were obtained with artificial models. EEP can be used to monitor the decellularization process after analyzing the varying EEP according to the amount of load. It was confirmed that the EEP was maintained at a high level in the experiment using the harvested lungs from 12-13-week-old rats. In addition, it was confirmed that the cell removal time was faster than when continuous perfusion was performed. In this study, pulsatile power delivered to the lungs was measured to monitor the process of cell removal, and it serve as the evidence for efficient decellularization.

목차

등록된 정보가 없습니다.

참고문헌 (24)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0