메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Shirali, Gholamabbas (Department of Occupational Health Engineering, Faculty of Public Health, Ahvaz Jundishapur University of Medical Sciences) Shekari, Mohammad (Department of Occupational Health Engineering, Faculty of Public Health, Ahvaz Jundishapur University of Medical Sciences) Angali, Kambiz Ahmadi (Department of Biostatistics and Epidemiology, Faculty of Public Health, Ahvaz Jundishapur University of Medical Sciences)
저널정보
산업안전보건연구원 Safety and health at work : SH@W Safety and health at work : SH@W 제9권 제3호
발행연도
2018.1
수록면
296 - 307 (12page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Background: Safety culture, acting as the oil necessary in an efficient safety management system, has its own weaknesses in the current conceptualization and utilization in practice. As a new approach, resilience safety culture (RSC) has been proposed to reduce these weaknesses and improve safety culture; however, it requires a valid and reliable instrument to be measured. This study aimed at evaluating the reliability and validity of such an instrument in measuring the RSC in sociotechnical systems. Methods: The researchers designed an instrument based on resilience engineering principles and safety culture as the first instrument to measure the RSC. The RSC instrument was distributed among 354 staff members from 12 units of an anonymous petrochemical plant through hand delivery. Content validity, confirmatory, and exploratory factor analysis were used to examine the construct validity, and Cronbach alpha and test-retest were employed to examine the reliability of the instrument. Results: The results of the content validity index and content validity ratio were calculated as 0.97 and 0.83, respectively. The explanatory factor analysis showed 14 factors with 68.29% total variance and 0.88 Kaiser-Meyer-Olkin index. The results were also confirmed with confirmatory factor analysis (relative Chi-square = 2453.49, Root Mean Square Error of Approximation = 0.04). The reliability of the RSC instrument, as measured by internal consistency, was found to be satisfactory (Cronbach ${\alpha}=0.94$). The results of test-retest reliability was r = 0.85, p < 0.001. Conclusion: The results of the study suggest that the measure shows acceptable validity and reliability.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0