메뉴 건너뛰기
Library Notice
Institutional Access
If you certify, you can access the articles for free.
Check out your institutions.
ex)Hankuk University, Nuri Motors
Log in Register Help KOR
Subject

A Case Study of National Indoor Air Certification for Multi-purpose Facility, and Suggestions for Improvement
Recommendations
Search
Questions

다중이용시설의 환경부 실내공기 우수시설 인증 사례분석 및 제도 개선 제언

논문 기본 정보

Type
Academic journal
Author
Young-Jin Kim (Korea Institute of Marine Science and Technology Promotion (KIMST)) Sean Hay Kim (Seoul National University of Science and Technology)
Journal
Korea Institute of Ecological Architecture and Environment KIEAE Journal Vol.22 No.2 (Wn.114) KCI Accredited Journals
Published
2022.4
Pages
63 - 68 (6page)
DOI
10.12813/kieae.2022.22.2.063

Usage

cover
📌
Topic
📖
Background
🔬
Method
🏆
Result
A Case Study of National Indoor Air Certification for Multi-purpose Facility, and Suggestions for Improvement
Ask AI
Recommendations
Search
Questions

Research history (2)

  • Are you curious about the follow-up research of this article?
  • You can check more advanced research results through related academic papers or academic presentations.
  • Check the research history of this article

Abstract· Keywords

Report Errors
Purpose: National Indoor Air Certification was introduced to structure an IAQ (Indoor Air Quality) management system for multi-purpose facility that experiences a difficulty in managing IAQ due to floating population. Although its demo projects ended in a seize in 2018, it is expected to restart in the near future. From previous demo projects, many existing facilities that are aged and lack of required records and document were not successful to achieve the certification, even if their IAQ were under decent management. This study aims to present some suggestions of improvement over the existing certification system. Method: Firstly, organization and procedure of the certification were investigated based on author"s experience who is involved in demo project operations. Then, cases of the 2018 demo project were thoroughly analyzed per each primary step. The analysis focuses on identifying practical limits in application and meeting the requirements, irrationales in gaining extra points from field evaluation, misalignment between field evaluation criteria and measured IAQ, and others. Result: This study concludes with suggesting six primary improvements for procedure and criteria of the certification, including providing a separate set of certification criteria for existing facilities and facilities smaller than the legal minimum of certification.

Contents

ABSTRACT
1. 연구의 배경 및 목적
2. 실내공기 우수시설 인증 기준 분석
3. 2018년 실내공기 우수시설 시범사업 사례분석
4. 실내공기 우수시설 인증의 제도 개선 제언
5. 결론
Reference

References (0)

Add References

Recommendations

It is an article recommended by DBpia according to the article similarity. Check out the related articles!

Related Authors

Frequently Viewed Together

Recently viewed articles

Comments(0)

0

Write first comments.

UCI(KEPA) : I410-ECN-0101-2022-610-001135739