메뉴 건너뛰기
Library Notice
Institutional Access
If you certify, you can access the articles for free.
Check out your institutions.
ex)Hankuk University, Nuri Motors
Log in Register Help KOR
Subject

Seismic Fragility Assessment for Korean High-Rise Non-Seismic RC Shear Wall Apartment Buildings
Recommendations
Search

국내 고층 비내진 철근콘크리트 벽식 아파트의 지진취약도 평가

논문 기본 정보

Type
Academic journal
Author
Jeon Seong-Ha (인천대학교 산학협력단) Dong-Hyun Shin (인천대학교 일반대학원 건축학과) Park Ji-Hun (인천대학교)
Journal
Earthquake Engineering Society of Korea 한국지진공학회 논문집 한국지진공학회논문집 제24권 제6호 KCI Accredited Journals
Published
2020.11
Pages
293 - 303 (11page)
DOI
https://doi.org/10.5000/EESK.2020.24.6.293

Usage

cover
Seismic Fragility Assessment for Korean High-Rise Non-Seismic RC Shear Wall Apartment Buildings
Ask AI
Recommendations
Search

Abstract· Keywords

Report Errors
Seismic fragility was assessed for non-seismic reinforced concrete shear walls in Korean high-rise apartment buildings in order to implement an earthquake damage prediction system. Seismic hazard was defined with an earthquake scenario, in which ground motion intensity was varied with respect to prescribed seismic center distances given an earthquake magnitude. Ground motion response spectra were computed using Korean ground motion attenuation equations to match accelerograms. Seismic fragility functions were developed using nonlinear static and dynamic analysis for comparison. Differences in seismic fragility between damage state criteria including inter-story drifts and the performance of individual structural members were investigated. The analyzed building had an exceptionally long period for the fundamental mode in the longitudinal direction and corresponding contribution of higher modes because of a prominently insufficient wall quantity in such direction. The results showed that nonlinear static analyses based on a single mode tend to underestimate structural damage. Moreover, detailed assessments of structural members are recommended for seismic fragility assessment of a relatively low performance level such as collapse prevention. On the other hand, inter-story drift is a more appropriate criterion for a relatively high performance level such as immediate occupancy.

Contents

No content found

References (39)

Add References

Recommendations

It is an article recommended by DBpia according to the article similarity. Check out the related articles!

Related Authors

Recently viewed articles

Comments(0)

0

Write first comments.