메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Moon Dong-Kyu (Gyeongsang National University School of Medicine Gyeongsang National University Hospital) Jo Ho-Seung (Gyeongsang National University School of Medicine Gyeongsang National University Hospital) Lee Dong-Yeong (Barun Hospital Jinju) Kang Dong-Geun (Gyeongsang National University Changwon Hospital) Won Hee-Chan (Gyeongsang National University Hospital) 서민석 (Department of Orthopaedic Surgery Gyeongsang National University Hospital Gyeongsang National Unive) Hwang Sun-Chul (Gyeongsang National University School of Medicine Gyeongsang National University Hospital)
저널정보
대한슬관절학회 Knee Surgery and Related Research Knee Surgery and Related Research 제33권
발행연도
2021.1
수록면
13 - 13 (1page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Notchplasty is a surgical technique often performed during anterior cruciate ligament reconstruction (ACLR) with widening of the intercondylar notch of the lateral distal femur to avoid graft impingement. The purpose of this study was to correlate femoral-tunnel length with 3-dimensional (3D) drilling angle through the anteromedial (AM) portal with and without notchplasty.Computer data were collected from an anatomical study using 16 cadaveric knees. The anterior cruciate ligament (ACL) femoral insertion was dissected and outlined for gross anatomical observation. The dissected cadaveric knees were scanned by computed tomography (CT). Three-dimensional measurements were calculated using software (Geomagic, Inc., Research Triangle Park, NC, USA) and included the center of the ACL footprint and the size of the ACL femoral footprint. The femoral-tunnel aperture centers were measured in the anatomical posterior-to-anterior and proximal-to-distal directions using Bernard’s quadrant method. The ACL tunnel was created 3-demensionally in the anatomical center of femoral foot print of ACL using software (SolidWorks®, Corp., Waltham, MA, USA). The 8-mm cylinder?shaped ACL tunnel was rested upon the anatomical center of the ACL footprint and placed in three different positions: the coronal plane, the sagittal plane, and the axial plane. Finally, the effect of notchplasty on the femoral-tunnel length and center of the ACL footprint were measured. All the above-mentioned studies performed ACLR using the AM portal. The length of the femoral tunnels produced using the low coronal and high axial angles with 5-mm notchplasty became significantly shorter as the femoral starting position became more horizontal. The result was 30.38?±?2.11?mm on average at 20° in the coronal plane/70° in the axial plane/45° in the sagittal plane and 31.26?±?2.08?mm at 30° in the coronal plane/60° in the axial plane/45° in the sagittal plane, respectively, comparing the standard technique of 45° in the coronal/45° in the axial/45° in the sagittal plane of 32.98?±?3.04?mm ( P <?0.001). The tunnels made using the high coronal and low axial angles with notchplasty became longer than those made using the standard technique: 40.31?±?3.36?mm at 60° in the coronal plane/30° in the axial plane/45° in the sagittal plane and 50.46?±?3.13?mm at 75° in the coronal plane/15° in the axial plane/45° in the sagittal plane ( P <?0.001). Our results show that excessive notchplasty causes the femoral tunnel to be located in the non-anatomical center of the ACL footprint and reduces the femoral-tunnel length. Therefore, care should be taken to avoid excessive notchplasty when performing this operation.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0