메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술대회자료
저자정보
Juan, Garcia-Olmo (SCAI [NIR/MIR Unit]. University of Cordoba.) Ana, Garrido-Varo (Department of Animal Production. Faculty of Agriculture and Forestry Engineering. University of Cordoba) Emiliano, De-Pedro (Department of Animal Production. Faculty of Agriculture and Forestry Engineering. University of Cordoba)
저널정보
한국근적외분광분석학회 한국근적외분광분석학회 학술발표회 한국근적외분광분석학회 2001년도 NIR-2001
발행연도
2001.1
수록면
1,243 - 1,243 (1page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
During two consecutive years, it was developed global calibrations for the prediction of fatty acids on Iberian pig fat. These equations should analyse well samples of that animal fat because of their high accuracy (SECV<SUB>C16:0</SUB> = 0.26%; SECV<SUB>C18:0</SUB> = 0.28%; SECV<SUB>C18:1</SUB> = 0.26%; SECV<SUB>C18:2</SUB> = 0.15%) and their broad covering composition range. In some cases, when new samples are predicted H (Mahalanobis distance) values higher than 3 (recommended value for agricultural products by the ISI software) are obtained. However, there are not any obvious factors which tells that samples scanned are very different to the spectral mean of the calibration population. Furthermore, these samples are well predicted according to the SEP values. The objective of the present work is to deepen the understanding of the H statistic when analysing animal fats. Three different validation files were predicted with equations obtained from January '97 to April '98. The Set A has spectra of 20 samples not included on the calibration file and scanned in May of 1998. The Set B has spectra of 20 samples included on the calibration file and scanned again in November '99. The Set C contains 150 spectra of one sample representative of the mean values (for fatty acids composition) of the calibration file. This sample was analysed three times per week during June '99 to July '00. The H mean values for the Set A, Set B and Set C were respectively 1.35, 14.39 and 11.71. These anomalous values for the Set B and C make not sense because Set B contains replicate subsamples of the same samples scanned during calibration development and Set C only contains spectra of one sample which represent the mean spectrum of the calibration files. Results will be shown to demonstrate that small day to day variations are responsible of the high H values. When a PCA and LIB file are created with calibration samples and spectra of the Set C modelling day to day variations, the H values for Set A, Set B and Set C were respectively 1.83, 2.16 and 0.93.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0