메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술대회자료
저자정보
저널정보
한국근적외분광분석학회 한국근적외분광분석학회 학술발표회 한국근적외분광분석학회 2001년도 NIR-2001
발행연도
2001.1
수록면
3,124 - 3,124 (1page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
The development and evolution of near infra-red spectroscopic (NIS) calibrations for high-moisture materials is an expensive proposition. Such investment is suspect unless the instrument, or instruments, on which calibrations were developed can be preserved intact or re-standardized as component replacements occurs. The objective of this paper is to detail the changes in performance of a six-year old instrument after maintenance in years five and six resulted in collection of spectral data that was increasingly removed from the calibration population. Calibrations for the analysis of mature sugarcane stalks, a high-moisture material, were developed successfully in 1995 using a broad sample population in terms of genetics, and spectral and temporal variation. The spectral library was further broadened in 1996. In 1997, 1999, 1999, and 2000, additional samples constituting 10% of the laboratories throughput were subjected to full component analyses using routine laboratory techniques. These samples were primarily random samples, but were complemented with samples that were significant for the spectral H statistic or for the component t statistic. In 1998, an additional calibration was developed for populations consisting of samples of either mature stalks (culms) or sucker culms. Substantial additional samples numbers were collected for this calibration in 1999 and 2000. Attempts to standardize the scanning spectrophotometer used for these calibrations with a second similar instrument in 1999 failed because the instruments were optically different, and standardization could not account for this. Maintenance adjustments were made to the remote reflectance probe of the original instrument in 1999, and replacement of its PbS detectors was done in 2000. Spectral data collected in 1999 and 2000 yielded spectral populations that were increasingly removed from the respective spectral populations on which the calibrations were developed. The mature stalk calibrations benefited marginally from evolutionary calib.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0